ISO6270-2冷凝水氣候試驗(yàn)箱技術(shù)參數(shù)
測(cè)試氣候條件 | 循環(huán)所需時(shí)間 | 為達(dá)到平衡狀態(tài)所需要的工作空間的狀態(tài) | ||||
名稱 | 縮寫 | 測(cè)試段 | 合計(jì) | 空氣溫度 | 相對(duì)濕度 | |
冷凝水-恒定氣候狀態(tài) | CH | 需要加熱至結(jié)束 | (40±3)℃ | 大約99%并伴有受測(cè)試體結(jié)露 | ||
交變氣候狀態(tài) | 伴有交變 空氣濕度 和空氣溫 度 | AHT | 包括8小時(shí)預(yù)熱 | 24小時(shí) | (40±3)℃ | 大約99%并伴有受測(cè)試體結(jié)露 |
包括16小時(shí)的冷卻 (將人工模擬氣候室打開并通風(fēng)) | 18 -28 ℃ | 低于99% | ||||
伴有交變 空氣溫度 | AT | 包括八小時(shí)預(yù)熱 | 24小時(shí) | (40±3)℃ | 大約99%并伴有受測(cè)試體結(jié)露 | |
包括16小時(shí)的冷卻 (人工模擬氣候室保持關(guān)閉) | 18 -28 ℃ | 大約99%(飽和) |
ISO6270-2冷凝水氣候試驗(yàn)箱優(yōu)點(diǎn) :
1、 Particularly energy-saving, heat-insulated compact chest-type design Housing and testing chamber made of high-quality glass-fibre reinforced polyester resin on fully laminated steel with castors and adjustable feet
特制的節(jié)能、隔熱緊湊型箱體設(shè)計(jì),內(nèi)置加強(qiáng)鋼架的高品質(zhì)玻璃纖維復(fù)合材料,標(biāo)配腳輪和可 調(diào)節(jié)地腳螺釘;
2、 Double-wall energy-saving testing chamber cover (particularly torsion-resistant and
providing insulation)
雙層節(jié)能箱蓋設(shè)計(jì)(特制防扭力、隔熱)
3、 Easy handling due to double gas strut support and ergonomically formed handle
方便的雙氣壓支撐桿,人體工學(xué)設(shè)計(jì)把手;
4、 Testing chamber volume approx. 1000 litre
試驗(yàn)容積大約 1000 升;
5、 Testing chamber seals made of foam silicone profiles
硅樹脂發(fā)泡密封
6、 Sample depot made of fully non-corrosive and deflection-resistant glass-fibre reinforced plastic round tubes
全防腐、防變形玻璃纖維加強(qiáng)型圓桿樣品架;
7、 Automatic refill system for deionized water to supply operating water for condensation
test.(Required flow pressure of deionized water: 0,5 - 1 bar)
冷凝水試驗(yàn)去離子水自動(dòng)上水系統(tǒng) (需要去離子水壓:0,5 - 1 bar)
8、 Large-surface heating on the outer down sides of the testing chamber protected against
corrosion for constant heating
箱體外下部的大加熱面積設(shè)計(jì),防止長(zhǎng)時(shí)間加熱狀態(tài)的腐蝕;
9、 Electronic micro-processor controlled temperature control (PID) of testing chamber
試驗(yàn) PID 溫度控制
10、 LED-Display resolution of set and actual value 0,1°C. Temperature constancy <± 0,5 K.
LED 顯示設(shè)定和實(shí)際溫度分辨率 0,1°C,溫度波動(dòng)小于± 0,5 K;
11、選項(xiàng):PID Temperature controller
用于連接設(shè)備到電腦,并自動(dòng)記錄數(shù)據(jù)
The chest is supplied fully equipped and ready for connection. The standard delivery scope includes: 3 m mist drainage hose d 50, 3 m safety overflow hose d 50, 2 m condensate drainage hose d 20
設(shè)備附件齊全,易于現(xiàn)場(chǎng)安裝。標(biāo)準(zhǔn)配置包括:3m長(zhǎng) d50 噴霧排水管,3m長(zhǎng) d50 溢流管,2m長(zhǎng) d20 冷凝排水管