德國Frizlen GmbH & Co. KG 電阻
德國FRAKO電容器
法國FERRAZ SHAWMUT熔斷器
:王工
同號
449147851
價(jià)注意事項(xiàng):
1.請發(fā)書面詢價(jià)函(郵件,,傳真等),不接受口頭報(bào)價(jià)。
2.如果型號不能*對上,請?zhí)峁┯⑽钠放泼?具體型號+數(shù)量。
3.詢價(jià)的商友請主動告知公司名稱和,謝謝。
UL Power Fuses
Class J - Time Delay - AJT MAXIMUM CIRCUIT PROTECTION, MINIMAL SIZE Amp-trap 2000® SmartSpot® AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides IEC Type "2" (No Damage) protection to main, feeder, and branch circuits, for all types of loads - yet, they require only half the mounting space needed for 600VAC Class RK fuses. | ||
Class L - Time Delay - A4BQ PUT THE HIGHEST CURRENT-LIMITATION... AT YOUR SERVICE. Amp-trap® 2000 A4BQ fuses are 20% more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in, 4-second time delay character (at 500% of rated current) accommodates harmless inrush currents without nuisance opening. | ||
Class CC - Transformer Duty - ATQR TAKE CONTROL OF FAULT CURRENTS HEADED FOR YOUR CONTROL TRANSFORMER. ATQR small-dimension fuses feature time delay characteristics ideally suited for the high inrush currents of control transformers, solenoids, and similar inductive loads. The newest member of our Amp-trap 2000® family of fuses - ATQR fuses provide superior protection for the branch circuits of electrical distribution systems. | ||
Class CC - Motor Duty - ATDR THE BEST PROTECTION FOR TODAY'S SMALL MOTORS. Amp-trap 2000® ATDR small-dimension fuses can provide IEC Type 2 "no damage" protection to your facility's increasingly sensitive branch circuit components and small motors - minimizing the risk of fault-related damage. ATDR Class CC fuses deliver the best time delay characteristics in their class with excellent cycling ability for small motor load. | ||
Class RK1 - Time Delay - A2D/A6D UPGRADE YESTERDAY'S CIRCUITS TO TODAY'S TYPE 2 PROTECTION. The Amp-Trap 2000® SmartSpot® A2D-R and A6D-R fuses feature a visual open fuse indicator and provide IEC Type 2 No Damage protection to main, feeder, and branch circuits for all types of loads. With time-delay characteristics for handling harmless in-rush currents, current-limiting ability and a wide range of ratings (from 1 to 600 Amperes), A2D-R and A6D-R fuses give excellent protection for all your applications. |
Blindleistungs-Kompensation | Power-Quality | Energie-Management |
FRAKO ist einer der weltweit führenden Hersler von Leistungs-Kondensatoren, Blindleistungs-Regelanlagen und Energie-Management-Systemen mit eigener Produktentwicklung. | FRAKO slt Ihre Power-Quality sicher mit aktiven und passiven Oberschwingungsfiltern, dynamischen Kompensationsanlagen und Netz-Analysatoren. | FRAKO bietet inligente Lösungen zur Optimierung der Energiekosten durch Analyse und Dokumentation des Energieverbrauchs und durch Überwachung des Versorgungsnetzes. |
Type series FZ / FU
TECHNICAL DESCRIPTIONCemented (FZ) and uncemented (FU) wirewound tubular fixed resistor, degree of protection IP00. Variable connections at the soldering, fast-on or screw clips on the resistor. | SPECIAL FEATURES• connection directly at the resistor | |
EXAMPLE OF USEThis unit is used as a ballast, limiting, filter or series resistor etc. for constructions and customer`s developments. |